Vicat softening temperature & HDT machine TVHT-A10

Vicat softening temperature & HDT testing machine TVHT-A10 with light weight and compact design, is adopted with advanced PID technology & photoelectric technology to control rise in temperature. Mainly used for the determination of temperature of thermal deformation (deflection) & vicat softening point of nonmetallic materials such as plastic, rubber, insulating materials. It is in accordance with international ISO, ASTM standards.

Buy Now View Catalog
Operating temperature Ambient temperature to 300°C
Heating rate 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
Maximum temp. error with heating speed ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
Range of deformation 0 to 10 mm
Deformation measurement method Digi gauge
Deformation accuracy 0.01 mm
Test station 3 stations
Heating medium Methyl silicon oil
Cooling method Wind cooling, neutral cooling, fast water cooling
Power supply AC220V, 50 Hz
  • Adopted with high precision temperature sensor
    Protection against over temperature
    Adopted with advanced PID technology & photoelectric technology
    Ensures error of heating speed is less than 0.5°C
    Software protection
    Digital dial gauge for accurate measurement

Vicat softening temperature & HDT testing machine is used in chemical & plastic industry, research institutes.

{"Operating temperature":"Ambient temperature to 300\u00b0C","Heating rate":"50\u00b0C\/ h (5 \u00b1 0.5\u00b0C\/ 6 min) , 120\u00b0C\/ h (12 \u00b1 1\u00b0C\/ 6 min)","Maximum temp. error with heating speed":"\u00b1 5\u00b0C under 50\u00b0C\/ h, \n\u00b1 1\u00b0C under 120\u00b0C\/ h","Range of deformation":"0 to 10 mm","Deformation measurement method":"Digi gauge","Deformation accuracy":"0.01 mm","Test station":"3 stations","Heating medium":"Methyl silicon oil","Cooling method":"Wind cooling, neutral cooling, fast water cooling","Power supply":"AC220V, 50 Hz"}
Adopted with high precision temperature sensor
Protection against over temperature
Adopted with advanced PID technology & photoelectric technology
Ensures error of heating speed is less than 0.5°C
Software protection
Digital dial gauge for accurate measurement
Vicat softening temperature & HDT testing machine is used in chemical & plastic industry, research institutes.


Related Products of Plastic Testing Instruments

Charpy/ Izod Impact Tester TCI-A10

Charpy/ Izod Impact Tester TCI-A10

Impact Speed & Energy (charpy) : 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J

Impact energy (Izod) : 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J

Resolution of impact energy : 0.001 J

Falling Weight Impact Tester TFWT-A10

Falling Weight Impact Tester TFWT-A10

Temperature range : 10 to 35°C

Maximum falling height : 2000 mm

Resolution of displacement : 1 mm

Heat sealer THS-A10
Heat sealer THS-A10

Seal temperature : Room temperature -250°C

Control accuracy : ± 0.2°C

Dwell time : 0.1 S to 999.9 S

Vacuum Leak Tester TVLT-A10
Vacuum Leak Tester TVLT-A10

Vacuum degree : 0 to 90 KPa

Accuracy : 1 % FS

Resolution : 0.1 KPa

Melt flow Indexer TMFI-A11

Melt flow Indexer TMFI-A11

Measuring range : 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)

Measuring rate : 0.001 S

Temperature range : 50 to 400°C

Melt flow Indexer TMFI-A10

Melt flow Indexer TMFI-A10

Measuring range : 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)

Measuring rate : 0.001 S

Temperature range : 50 to 400°C

Lasting adhesive tester TLAT-A11
Lasting adhesive tester TLAT-A11

Standard roller : 2000 ± 50 g

Testing stations : 6

Dimension (L*W*H) tester : 650×210×550 mm (6 stations)

Lasting adhesive tester TLAT-A10
Lasting adhesive tester TLAT-A10

Standard roller : 2000 ± 50 g

Testing stations : 3

Dimension (L*W*H) tester : 320×210×550 mm (3 stations)

Soil Testing Instruments

Soil nutrient tester TSNA-A11

Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %

Soil nutrient tester TSNA-A10

Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %

Other Testing Instruments

Benchtop gloss meter TBGM-A10
Test angle 60°
Gloss aperture 2 × 3 mm
Measurement range 0 to 1000 GU

Paper Testing Instruments

Whiteness meter TP-A11
Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
System D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source D65 as illuminating source

Whiteness and chromaticity tester TP-A10

Sample (size) length Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability ≤ 0.1 within 30 min

Rubber Testing Instruments

Three roll mill machine TRMM-A10

Mixed capacity 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range RT to 300°C
Temperature control system PID control
Rubber Low Temperature Brittleness Tester TRBT-A11
Temperature control range Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy ± 0.3 ℃
Impact speed 0℃ to -30℃ around 2.5 ℃/min
-30℃ to -40℃ around 2.5 ℃/min
-40℃ to -70℃ around 2.0 ℃/min

NDT Testing Instruments

Rockwell hardness meter TRHM-A10
Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 0 to 30 S

Rockwell hardness meter TRHM-A11

Preliminary test force 98 N
Total test force 588, 980, 1471 N
Total test force dwell time 1 to 30 S

Talk to us?