Analytical HPLC System LAHS-B10 is a unit equipped with LCD display UV-Visible wavelength range of 190 nm to 700 nm and double plunger reciprocating pump system for constant flow pump. It has isocratic kit system for test result accuracy. Consists of separate workstation, sample injector and front mounted self-locking switch. Deuterium lamp is used as light source with valve mounting frame. It is ideally used in the detection of compounds in pharmaceutical industries, research institute, food industries, and petroleum industries, etc.
Buy Now View Catalog| High Pressure Constant Flow Pump |
|
| UV/Visible Detector |
|
| No | Accessory name |
| 1 | Column oven |
Widely used in pharmaceutical, petroleum, research institute, food industrial applications in separation and detection of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.
Pump Specifications :
Detector Specifications :
Pump specification :
UV/VIS Detector :
Data-processing Workstation : System contain the tables for regular samples
Equipped with Internal and external standard calculation process
Automatic display, print, export of data and starting of another program on completion on measurement
Observe with the condition of 21 CFR part 11 directive of the FDA
High Pressure Constant Flow Pump :
UV/Visible Detector :
Detector Specifications :
| Model No | HPD-A20 | HPD-A21 |
| Wavelength range | Single wavelength ( 190 to 800 nm ) | Dual wavelength ( 190 to 800 nm ) |
| Wavelength accuracy | ± 0.5 nm | ± 2 nm |
| Wavelength repeatability | 0.15 nm | 0.3 nm |
| Band width | 8 nm | 8 nm |
| Optical path | 10 nm | 10 nm |
| Deuterium lamp | 190 to 400 nm | 190 to 400 nm |
| Tungsten lamp | 400 to 800 nm | 400 to 800 nm |
| Baseline noise ( Static ) Au | ≤ ± 0.35 × 10-5 | ≤ ± 0.5 × 10-5 |
| Baseline drift ( Static ) Au / h | ≤ 1 × 10-4 | ≤ 1.5 × 10-4 |
| Minimum detection limit | ≤ 4 × 10-8 | ≤ 4 × 10-8 |
| Power | 100 W | 100 W |
| Power supply | 90 V / 50 to 60 Hz | 90 V / 50 to 60 Hz |
| Dimension | 460 × 315 × 180 mm | 460 × 315 × 180 mm |
| Weight | 9.5 kg | 9.5 kg |
Pump Specifications :
Pump Specifications :
Detector Specifications :
| High pressure pump | Single pump |
| Flow rate range | 0.001 - 9.999 mL / min (0.001 mL / min increment) |
| Pressure range | ≤ 0.5 MPa (0 - 42 MPa) |
| High pressure pump | Two sets of pump |
| Flow rate range | 0.001 - 9.999 mL / min (0.001 mL / min increments) |
| Pressure range | ≤ 0.5 MPa (0 - 42 MPa) |
Talk to us?