Analytical HPLC System LAHS-B10

Analytical HPLC System LAHS-B10 is a unit equipped with LCD display UV-Visible wavelength range of 190 nm to 700 nm and double plunger reciprocating pump system for constant flow pump. It has isocratic kit system for test result accuracy. Consists of separate workstation, sample injector and front mounted self-locking switch. Deuterium lamp is used as light source with valve mounting frame. It is ideally used in the detection of compounds in pharmaceutical industries, research institute, food industries, and petroleum industries, etc.

Buy Now View Catalog
High Pressure Constant Flow Pump
  • Double plunger reciprocating pump: 1 set
  • Flow range: 0.001 to 10.00 mL/min
  • Setting step size: 0.001 mL/min
  • Flow accuracy: ≤ ± 0.3 %
  • Flow stability: RSD ≤ 00.1 %
  • Maximum pressure: 42 MPa
  • Display pressure error: ≤ 1.0 %
  • Pressure fluctuation: ≤ 1.0 %
  • Power consumption: 80 W
UV/Visible Detector
  • Wavelength range: 190 to 700 nm
  • Wavelength repeatability: ± 0.1 nm
  • Band width: 8 nm
  • Response time: 0 to 4.9 seconds
  • Linearity range: 1.8 AU (5 %)
  • Baseline Noise: ≤ ± 1 × 10-5AU
  • Baseline drift: ≤ 2.0 × 10-4AU/h
  • Minimum detectable concentration: 4.0 × 10-9 g/mL
  • Detector cell: Optical path: 10 mm
    Volume: 10 µL
  • Light source: Deuterium lamp
  • Power consumption: 100 W
  • Voltage: AC 110 V/ 220 V ± 10 %, 50/60 Hz
  • Packing Dimensions (W × D × H): 600 × 440 × 380 mm
    2 × (600 × 410 × 300 mm
  • Gross weight: 54 kg
  • Double plunger reciprocating pump system
    Isocratic system kits
    Sample injector: 1 set
    Deuterium lamp light source
    Separate workstation
    LCD display for value observation
    Front mounted self-locking switch
    Output: USB port
    Compact and easy to install
No Accessory name
1 Column oven

Widely used in pharmaceutical, petroleum, research institute, food industrial applications in separation and detection of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.

{"High Pressure Constant Flow Pump":{"Double plunger reciprocating pump":"1 set","Flow range":"0.001 to 10.00 mL\/min","Setting step size":"0.001 mL\/min","Flow accuracy":"\u2264 \u00b1 0.3 %","Flow stability":"RSD \u2264 00.1 %","Maximum pressure":"42 MPa","Display pressure error":"\u2264 1.0 %","Pressure fluctuation":"\u2264 1.0 %","Power consumption":"80 W"},"UV\/Visible Detector":{"Wavelength range":"190 to 700 nm","Wavelength repeatability":"\u00b1 0.1 nm","Band width":"8 nm","Response time":"0 to 4.9 seconds","Linearity range":"1.8 AU (5 %)","Baseline Noise":"\u2264 \u00b1 1 \u00d7 10-5<\/sup>AU","Baseline drift":"\u2264 2.0 \u00d7 10-4<\/sup>AU\/h","Minimum detectable concentration":"4.0 \u00d7 10-9<\/sup> g\/mL","Detector cell":"Optical path: 10 mm
\nVolume: 10 \u00b5L","Light source":"Deuterium lamp","Power consumption":"100 W","Voltage":"AC 110 V\/ 220 V \u00b1 10 %, 50\/60 Hz","Packing Dimensions (W \u00d7 D \u00d7 H)":"600 \u00d7 440 \u00d7 380 mm
\n2 \u00d7 (600 \u00d7 410 \u00d7 300 mm","Gross weight":"54 kg"}}
Double plunger reciprocating pump system
Isocratic system kits
Sample injector: 1 set
Deuterium lamp light source
Separate workstation
LCD display for value observation
Front mounted self-locking switch
Output: USB port
Compact and easy to install
Widely used in pharmaceutical, petroleum, research institute, food industrial applications in separation and detection of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.


Related Products of Analytical HPLC

Analytical HPLC-A7835

Analytical HPLC-A7835

Pump Specifications :

  • Model No: HPP-B1
  • Flow rate range: 0.0001 to 10 ml / min
  • Maximum pressure: 42 MPa , 0 to 5 ml / min
  • Column size: 4.6 × 250 mm
  • Sample size: 5 μm
  • Pressure pulsation: ≤ 1.5 % at 10 MPa
  • Flow rate accuracy: ± 0.2 % at 1 ml / min
  • Flow rate repeatability %: ≤ 0.15
  • Gradient accuracy %: ± 2
  • Gradient repeatability %: ≤ 0.2
  • Dimension: 450 × 260 × 190 mm
  • Power supply: 90 V to 240 V
  • Weight: 11.2 kg

Detector Specifications :

  • Model No: HPD-B2
  • Wavelength range: 190 to 800 nm
  • Wavelength accuracy: ± 0.75 nm
  • Wavelength repeatability: 0.2 nm
  • Band width: 8 nm
  • Optical path: 10 nm
  • Deuterium lamp: 190 to 400 nm
  • Tungsten lamp: 400 to 800 nm
  • Baseline noise ( Static ) Au: ≤ ± 0.5 × 10 -5
  • Baseline drift ( Static ) Au / h: ≤ 1.5 x 10 -4
  • Minimum detection limit: ≤ 4 x 10 -8
  • Power: 100 W
  • Power supply: 90 V / 50 to 60 Hz
  • Dimension: 460 × 260 × 190 mm
  • Weight: 9.2 kg

Analytical HPLC System LAHS-A10

Analytical HPLC System LAHS-A10

Pump specification :

  • Type: Quaternary Low Pressure Pump
  • Flow Rate Range: 0.001 to 10.000 ml/min, in 0.001ml increments
  • Flow Accuracy: ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa)
  • Flow Precision: RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa)
  • Maximum Pressure: 63 MPa
  • Pressure accuracy: ≤ ± 3.0 %
  • Pressure pulsation: ≤ 0.1 MPa
  • Composition rang: 0 to 100 %
  • Composition precision: ≤ 0.3 % RSD

UV/VIS Detector :

  • Wavelength Range: 190 to 800 nm
  • Wavelength Repeatability: ≤ 0.1 nm
  • Wavelength Accuracy: ≤ ± 1.0 nm
  • Band Width: 6 nm
  • Response Time: 0.0 s to 5 s
  • Baseline Noise: ≤ ± 0.25 × 10-5 AU(empty cell, 254 nm, 1.0s)
  • Drift: ≤ 0.5 × 10-4 AU/h (empty cell, 254 nm, 60 min)
  • Path length: 10 mm(analytical cell)
  • Light Source: Deuterium Lamp and Tungsten Lamp

Data-processing Workstation : System contain the tables for regular samples
Equipped with Internal and external standard calculation process
Automatic display, print, export of data and starting of another program on completion on measurement
Observe with the condition of 21 CFR part 11 directive of the FDA

Analytical HPLC System LAHS-B11
Analytical HPLC System LAHS-B11

High Pressure Constant Flow Pump :

  • Double plunger reciprocating pump: 2 sets
  • Flow range: 0.001 to 10.00 mL/min
  • Setting step size: 0.001 mL/min
  • Flow accuracy: ≤ ± 0.3 %
  • Flow stability: RSD ≤ 00.1 %
  • Maximum pressure: 42 MPa
  • Display pressure error: ≤ 1.0 %
  • Pressure fluctuation: ≤ 1.0 %
  • Power consumption: 80 W

UV/Visible Detector :

  • Wavelength range: 190 to 700 nm
  • Wavelength repeatability: ± 0.1 nm
  • Band width: 8 nm
  • Response time: 0 to 4.9 seconds
  • Linearity range: 1.8 AU (5 %)
  • Baseline Noise: ≤ ± 1 × 10-5AU
  • Baseline drift: ≤ 2.0 × 10-4AU/h
  • Minimum detectable concentration: 4.0 × 10-9 g/mL
  • Detector cell: Optical path: 10 mm
    Volume: 10 µL
  • Light source: Deuterium lamp
  • Power consumption: 100 W
  • Voltage: AC 110 V/ 220 V ± 10 %, 50/60 Hz
  • Packing Dimensions (W × D × H): 600 × 440 × 380 mm
    3 × (600 × 410 × 300 mm
  • Gross weight: 75 kg

Analytical HPLC-A7832
Analytical HPLC-A7832

Detector Specifications :

Model No HPD-A20 HPD-A21
Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm )
Wavelength accuracy ± 0.5 nm ± 2 nm
Wavelength repeatability 0.15 nm 0.3 nm
Band width 8 nm 8 nm
Optical path 10 nm 10 nm
Deuterium lamp 190 to 400 nm 190 to 400 nm
Tungsten lamp 400 to 800 nm 400 to 800 nm
Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5
Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4
Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8
Power 100 W 100 W
Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz
Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm
Weight 9.5 kg 9.5 kg

Pump Specifications :

  • Flow rate range: 0.0001 to 10 ml / min
  • Maximum pressure: 50 MPa , 0 to 2 ml / min
  • Column size: 4.6 × 250 mm
  • Sample size: 5 µm
  • Pressure pulsation: ≤ 1 % at 10 MPa
  • Flow rate accuracy: ± 0.15 % at 1 ml / min
  • Flow rate repeatability %: ≤ 0.1
  • Gradient accuracy %: ± 1.5
  • Gradient repeatability %: ≤ 0.2
  • Dimension: 460 × 310 × 180 mm
  • Power supply: 90 V
  • Weight: 11.6 kg

Analytical HPLC-A7840

Analytical HPLC-A7840

Pump Specifications :

  • Solvent delivery: Double plunger series mode, floating plunger design, single stroke volume 30 µl
  • Pump Head: 10 ml stainless steel pump head
  • Flow rate range: 0.001 to 9.999 ml / min
  • Flow rate increment: 0.001 ml/min
  • Maximum pressure: 42 MPa
  • Column size: 4.6 × 250 mm 5 µm
  • Pipeline Size: 1/16 inch
  • Flow rate accuracy: ± 0.5 %
  • Flow rate precision: RSD ≤ 0.1%
  • Gradient accuracy %: ± 0.5 %
  • Gradient repeatability %: RSD ≤ 0.15%
  • GLP: Automatic recording of pump sealing ring working time
  • Display: LCD backlight display
  • Power: 80 W
  • Power supply: 220 V ± 10%, 50 Hz
  • Dimension: 398 × 149 × 267 mm

Detector Specifications :

  • Wavelength range: 190 to 700 nm
  • Wavelength accuracy: ± 1 nm
  • Wavelength repeatability: 0.2 nm
  • Deuterium lamp: 190 to 400 nm
  • Tungsten lamp: 400 to 700 nm
  • Baseline noise ( Static ) Au: 1 × 10-5 AU/h at 254 nm with methanol/water= 80/20
  • Baseline drift ( Static ) Au / h: 1.5 × 10-4 AU/h at 254 nm with methanol/ water= 80/20
  • Time constants: 16 grades adjustable
  • Display: LCD backlight display
  • GLP: Total number of lights, lamp replacement time and product serial number
  • Power: 75 W
  • Power supply: 220 V ± 10%, 50 Hz
  • Dimension (L × W × H): 398 × 149 × 267 mm

Standard HPLC

HPLC system LHLC-A10

High pressure pump Single pump
Flow rate range 0.001 - 9.999 mL / min (0.001 mL / min increment)
Pressure range ≤ 0.5 MPa (0 - 42 MPa)

HPLC system LHLC-A11

High pressure pump Two sets of pump
Flow rate range 0.001 - 9.999 mL / min (0.001 mL / min increments)
Pressure range ≤ 0.5 MPa (0 - 42 MPa)

Talk to us?