2 <\/sub>O, R.T., 8.5 MPa)","Flow Precision":"RSD \u2264 0.06% (1.00 ml\/min, H2 <\/sub>O, R.T., 8.5MPa)","Maximum Pressure":"63 MPa","Pressure accuracy":"\u2264 \u00b1 3.0 %","Pressure pulsation":"\u2264 0.1 MPa","Composition rang":"0 to 100 %","Composition precision":"\u2264 0.3 % RSD"}, UV/VIS Detector: {"Wavelength Range":"190 to 800 nm","Wavelength Repeatability":"\u2264 0.1 nm","Wavelength Accuracy":"\u2264 \u00b1 1.0 nm","Band Width":"6 nm","Response Time":"0.0 s to 5 s","Baseline Noise":"\u2264 \u00b1 0.25 \u00d7 10-5 <\/sup> AU(empty cell, 254 nm, 1.0s)","Drift":"\u2264 0.5 \u00d7 10-4 <\/sup> AU\/h (empty cell, 254 nm, 60 min)","Path length":"10 mm(analytical cell)","Light Source":"Deuterium Lamp and Tungsten Lamp"}, Data-processing Workstation: System contain the tables for regular samples
Equipped with Internal and external standard calculation process
Automatic display, print, export of data and starting of another program on completion on measurement
Observe with the condition of 21 CFR part 11 directive of the FDA. Explore the product to find out more. Visit labtron.uk!"> Analytical HPLC System LAHS-A10 Catalog | Labtron 2 <\/sub>O, R.T., 8.5 MPa)","Flow Precision":"RSD \u2264 0.06% (1.00 ml\/min, H2 <\/sub>O, R.T., 8.5MPa)","Maximum Pressure":"63 MPa","Pressure accuracy":"\u2264 \u00b1 3.0 %","Pressure pulsation":"\u2264 0.1 MPa","Composition rang":"0 to 100 %","Composition precision":"\u2264 0.3 % RSD"}, UV/VIS Detector: {"Wavelength Range":"190 to 800 nm","Wavelength Repeatability":"\u2264 0.1 nm","Wavelength Accuracy":"\u2264 \u00b1 1.0 nm","Band Width":"6 nm","Response Time":"0.0 s to 5 s","Baseline Noise":"\u2264 \u00b1 0.25 \u00d7 10-5 <\/sup> AU(empty cell, 254 nm, 1.0s)","Drift":"\u2264 0.5 \u00d7 10-4 <\/sup> AU\/h (empty cell, 254 nm, 60 min)","Path length":"10 mm(analytical cell)","Light Source":"Deuterium Lamp and Tungsten Lamp"}, Data-processing Workstation: System contain the tables for regular samples
Equipped with Internal and external standard calculation process
Automatic display, print, export of data and starting of another program on completion on measurement
Observe with the condition of 21 CFR part 11 directive of the FDA. Explore the product to find out more. Visit labtron.uk!"> 2 <\/sub>O, R.T., 8.5 MPa)","Flow Precision":"RSD \u2264 0.06% (1.00 ml\/min, H2 <\/sub>O, R.T., 8.5MPa)","Maximum Pressure":"63 MPa","Pressure accuracy":"\u2264 \u00b1 3.0 %","Pressure pulsation":"\u2264 0.1 MPa","Composition rang":"0 to 100 %","Composition precision":"\u2264 0.3 % RSD"}, UV/VIS Detector: {"Wavelength Range":"190 to 800 nm","Wavelength Repeatability":"\u2264 0.1 nm","Wavelength Accuracy":"\u2264 \u00b1 1.0 nm","Band Width":"6 nm","Response Time":"0.0 s to 5 s","Baseline Noise":"\u2264 \u00b1 0.25 \u00d7 10-5 <\/sup> AU(empty cell, 254 nm, 1.0s)","Drift":"\u2264 0.5 \u00d7 10-4 <\/sup> AU\/h (empty cell, 254 nm, 60 min)","Path length":"10 mm(analytical cell)","Light Source":"Deuterium Lamp and Tungsten Lamp"}, Data-processing Workstation: System contain the tables for regular samples
Equipped with Internal and external standard calculation process
Automatic display, print, export of data and starting of another program on completion on measurement
Observe with the condition of 21 CFR part 11 directive of the FDA. Explore the product to find out more. Visit labtron.uk!">

Analytical HPLC System LAHS-A10 Catalog

Download Catalog

Analytical HPLC System LAHS-A10

Overview

Analytical HPLC System LAHS-A10 features Quaternary Low Pressure Pump with 0.001-10 ml/min pump flow rate. Incorporated UV-Vis detector with a range of 190 to 800 nm that examines sample absorption at different wavelengths and a high pressure pump providing continuous stable flow. This HPLC system offers high speed accuracy, resolving power, detection, quantification, convenience and applicability to new sample types. 

Features :

  • UV-Vis detector with a range of 190 to 800 nm
    Consist of Quaternary Low Pressure Pump
    Advance and intellectual HPLC system
    Excellent Flow Accuracy and Pressure Accuracy
    Column oven with greater capacity of 3 column with maximum thickness ID10 × 250 mm
    Fast and stable UDP communication protocol, can be used for instrument remote control
    Enhancement of up to 5 mm stroke of plunger rod with good performance and high pressure constant flow pump or parallel pump head
    Complies with FDA 21 CFR part 11
  • Specifications :
    Pump specification
    • Type: Quaternary Low Pressure Pump
    • Flow Rate Range: 0.001 to 10.000 ml/min, in 0.001ml increments
    • Flow Accuracy: ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa)
    • Flow Precision: RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa)
    • Maximum Pressure: 63 MPa
    • Pressure accuracy: ≤ ± 3.0 %
    • Pressure pulsation: ≤ 0.1 MPa
    • Composition rang: 0 to 100 %
    • Composition precision: ≤ 0.3 % RSD
    UV/VIS Detector
    • Wavelength Range: 190 to 800 nm
    • Wavelength Repeatability: ≤ 0.1 nm
    • Wavelength Accuracy: ≤ ± 1.0 nm
    • Band Width: 6 nm
    • Response Time: 0.0 s to 5 s
    • Baseline Noise: ≤ ± 0.25 × 10-5 AU(empty cell, 254 nm, 1.0s)
    • Drift: ≤ 0.5 × 10-4 AU/h (empty cell, 254 nm, 60 min)
    • Path length: 10 mm(analytical cell)
    • Light Source: Deuterium Lamp and Tungsten Lamp
    Data-processing Workstation System contain the tables for regular samples
    Equipped with Internal and external standard calculation process
    Automatic display, print, export of data and starting of another program on completion on measurement
    Observe with the condition of 21 CFR part 11 directive of the FDA
    System Kits 1 Set
    Combined A/D converters
    Combined vacuum degasser and 4 channel
    Power Supply AC 110 /220 V ±1 0 %, 50/60 Hz
    Dimension 710 × 583× 500mm; 770 × 450 × 700 mm
    Weight 156 kg
    Standard Accessories :

    Degasser

    Optional Accessories :

    Accessories no. Name
    1 Column oven
    2 Auto sampler
    3 Degasser
    4 Diode Array Detector
    5 Refractive Index Detector
    6 Evaporative Light Scattering Detector
    7 Fluorescence Detector

    Applications :

    High Performance Liquid Chromatography system has been widely used in Research and Development, pharmaceutical, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity.

    Labtron
    • Labtron Equipment Ltd Quatro House, Lyon Way,Camberley, Surrey GU16 7ER United KingdomQuatro House, Lyon Way,Camberley, Surrey GU16 7ER United Kingdom
    • Email: info@labtron.uk | Website: www.labtron.uk